DES-7200 Hardware Installation Guide
1-24
Warning
7200-48P does not support the hot pull-out operation. You need to perform
the following operations to achieve it:
1. Disconnect all cables connected to the cable card ports;
2. Hold the Mode button for over three seconds until all LEDs on the
cable card ports go off;
3. Configure the pull-out operation through software commands. (For
relevant software configuration commands, refer to the corresponding
software description.)
2. LEDs
The 7200-48P provides various system LEDs, as described in the following table:
Table 1-16 LEDs on the Front Panel
Sign Description Detailed Information
Status System LED
OFF: The module has not been powered on.
Red: Module fault
Flashing green: The module is initializing.
Solid gr een: T he m odule ha s f inished i nitialization and can
perform switching normally.
Mode LED status indication
Green: Data exchange indication
Orange: PoE status indication
Link/ACT Port status LED
Electrical interface:
When Mode is green (switching):
OFF: Port is not linked.
Green: Port is linked at 1000M.
Yellow: Port is linked at 10/100M.
Flashing: Data is transmitted on the port.
When Mode is orange (PoE):
Off: The PoE device does not work normally.
Green: The PoE device works normally.
Yellow: the PoE device is overloaded.
Red: The port cannot be powered.
Optical interface:
OFF: Port is not linked.
Green: Port is linked.
Flashing green: Data is transmitted on the port.
3. Technical Specifications
Table 1-17 Technical Specifications of the 7200-48P
Product Model
7200-48P
Standard
Compliance
IEEE 802.3-2000
IEEE 803.ab, IEEE 802.3af, IEEE 802.1D and IEEE 802.1Q
802.1X authentication
Port type
44 10/100/1000BASE-T el ectrical 1000M interfaces and 4 optical/electrical
combo 1000M interfaces;
Up to 48 1000BASE-T interfaces, or 44+M 1000BASE-T interfaces and N
1000BASE-X interfaces where M plus N equals to 4.
Up to 48 PoE ports.