D-Link DSA-3100P - B/W Thermal Line Printer Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Networking D-Link DSA-3100P - B/W Thermal Line Printer. Artis zee floor-surg V2 engl.indd Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 32
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
s
www.siemens.com/healthcare
Artis zee
Floor-mounted system for surgical angiography
VC 14
Data sheet
Przeglądanie stron 0
1 2 3 4 5 6 ... 31 32

Podsumowanie treści

Strona 1 - Artis zee

swww.siemens.com/healthcareArtis zeeFloor-mounted system for surgical angiographyVC 14Data sheet

Strona 2

10Artis zeeFloor-mounted system for surgical angiographyOperating modes FluoroscopyDigital pulsed fluoroscopy, with 10, 15, 30 P/s in 1k/12-bit matrix

Strona 3

11Artis zeeFloor-mounted system for surgical angiographyOperating modesPERISTEPPING* (only with 30 x 40 flat detector)Peripheral digital angiography s

Strona 4

12Artis zeeFloor-mounted system for surgical angiographyAdditional functionsECG recording and storage* Recording, storage, and display of an ECG wavef

Strona 5

13Artis zeeFloor-mounted system for surgical angiographyQuantificationQVA – Vascular analysis for vessel diameters of 3 mm – 42 mm* (not for coronary

Strona 6

14Artis zeeFloor-mounted system for surgical angiographysyngo DynaCT*syngo X Workplace For reconstruction of two-dimensional images acquired via Artis

Strona 7

15Artis zeeFloor-mounted system for surgical angiography* OptionDICOM FunctionsDICOM SendSends images and series to DICOM networks or workstationsDICO

Strona 8

16Artis zeeFloor-mounted system for surgical angiographyCARECAREMATICAutomatic X-ray control system for fully automatic calculation and optimization o

Strona 9

17Artis zeeFloor-mounted system for surgical angiographyOperationIn the examination roomComplete system operation via modular control elements at the

Strona 10

Artis zeeFloor-mounted system for surgical angiography+ Modular choice (several variations to choose from)18Flat detector 20 x 20+Solid-state amorpho

Strona 11

19Artis zeeFloor-mounted system for surgical angiographyLaser crosshairs*Laser crosshairs for FD 30 x 40, integrated into the flat detector housing wi

Strona 12

Artis zeeFloor-mounted system for surgical angiography2The Artis zee floor-mounted system is specifically designed to meet the escalating demands of h

Strona 13

20Artis zeeFloor-mounted system for surgical angiographyX-ray tubeMEGALIX Cat 125/35/80-121GW (for the 20 x 20 detector)High-performance X-ray tube wi

Strona 14

21Artis zeeFloor-mounted system for surgical angiographyX-ray tubeMEGALIX Cat Plus 125/40/90-122GW (for the 20 x 20 detector)**High-performance X-ray

Strona 15

22Artis zeeFloor-mounted system for surgical angiographyX-ray tubeMEGALIX Cat Plus 125/20/40/80-122GW (for the 30 x 40 detector)**High-performance X-r

Strona 16

23Artis zeeFloor-mounted system for surgical angiographyDCS-extended*Ceiling-mounted suspension system DCS-extended for 3 to 8 displays enables height

Strona 17

24Artis zeeFloor-mounted system for surgical angiographyArtis zee Large Display*DSC 5608-DC56“ viewing area enables a new dimension in medical imaging

Strona 18

25Artis zeeFloor-mounted system for surgical angiographyInjectorsMEDRAD Avanta*Contrast medium syringe 150 mlContrast flow mode fixed 1 to 45 ml/s,

Strona 19

26Artis zeeFloor-mounted system for surgical angiographyInjectorsANGIOMAT Illumena*Contrast medium syringe 150 mlFlow rates 0.1 ml/s to 9.9 ml/s in

Strona 20

27Artis zeeFloor-mounted system for surgical angiographyRemote Service*Preparation for Siemens Remote Service (SRS):Allowed hardware and software remo

Strona 21

28Artis zeeFloor-mounted system for surgical angiographyPower unit for generator A100 UN / P 100 kW 80 kW 380 V* ≤ 0.08 Ohm ≤ 0.10 Ohm 400 V*

Strona 22

29Artis zeeFloor-mounted system for surgical angiographyAmbient conditions (operation)Examination and control room Temperature range: + 15°C to + 30

Strona 24

30Artis zeeFloor-mounted system for surgical angiographySystem positionsHead-end positionLeft-side positionPatient transfer positionRight-side table r

Strona 25

31Artis zeeFloor-mounted system for surgical angiographySystem view (mm)Room layout (mm)216010601269RH 2600 - 3100775 - 11001195max. 1580max. system h

Strona 26

www.siemens.com/healthcareGlobal Siemens Healthcare HeadquartersSiemens AGHealthcare SectorHenkestrasse 127D-91052 ErlangenGermanyTelephone +49 9131 8

Strona 27

4Maximizing coverage and positioning flexibility with Multispace.F*Multispace.F for the Artis zee floor-mounted system allows for additional examinati

Strona 28

53D imaging and intuitive guidance1The Artis zee imaging chain enables a range of advanced 3D applications – from cross-sectional imaging of soft tiss

Strona 29

6Artis zeeFloor-mounted system for surgical angiographyStandThe Artis zee floor angio system is specifically designed to meet the escalating demands o

Strona 30

7Artis zeeFloor-mounted system for surgical angiographyPatient tablesDepending on the diagnostic and therapeutic focus, the various patient table con

Strona 31

Artis zeeFloor-mounted system for surgical angiography+ Modular choice (several variations to choose from)8TabletopsThree carbon-fiber tabletops with

Strona 32 - (For U.S. and Canada)

9Artis zeeFloor-mounted system for surgical angiographyImaging system High-resolution digital imaging system with outstanding image quality due to rea

Komentarze do niniejszej Instrukcji

Brak uwag